A GPU server reports a power supply fault, and the node still runs on its remaining supplies. What is the right handling?
- Exam domain
- Troubleshooting and Optimization12% of the exam
- Difficulty
- Medium
- In this mock
- 7 questions on this domainPractise this domain
Why the exam asks this
Troubleshooting and Optimization (12% of the exam).
Objective in the exam guide: Identify faulty cards/GPUs/power supplies
Power supply faults are named in the topics.
Why C is the answer
Confirm the faulty supply from the BMC sensors and event log, then replace it following the system service procedure
The BMC identifies the failed supply; replacing it promptly restores redundancy before a second failure takes the node down.
How it works
Servers often have several power supplies for redundancy.
The BMC reports supply status and logs faults.
A failed supply should be replaced to restore redundancy.
Clues in the question
The words that point to the answer, and what each one tells you.
- Still runs on remaining supplies
- Redundancy is reduced.
In detail
- Plan the replacement to avoid interrupting jobs where possible.
- Check whether the facility circuit is the cause.
Side by side with look-alikes
| Action | Sound? |
|---|---|
| Confirm in BMC, replace | Yes |
| Ignore | No |
| Raise GPU power | No |
| Reinstall driver | No |
Every option, checked
Knowing why each wrong option fails is how you rule it out on exam day.
A. Raise the GPU power limits to compensateWrong
More power draw on fewer supplies adds risk.
B. Reinstall the GPU driverWrong
Drivers do not affect power supplies.
C. Confirm the faulty supply from the BMC sensors and event log, then replace it following the system service procedureRight
The BMC identifies the failed supply; replacing it promptly restores redundancy before a second failure takes the node down.
D. Ignore it because the node is still runningWrongMost tempting
Running without redundancy risks an outage.
Why it tempts: It works now. But one more failure could take it down.
In practice
- Alert on PSU events, not only on node down events.